Meter ComparisonsKey Differences Between the New ADM-870C and the ADM-870
  Shortridge Instruments, Inc.AIR FLOW  Shortridge Instruments, Inc.VELOCITY   Shortridge Instruments, Inc.PRESSURE  Shortridge Instruments, Inc.TEMPERATURE

METER COMPARISONS 

KEY DIFFERENCES BETWEEN
THE NEW ADM-870C and THE ADM-870


RS232 TO PORTABLE PRINTER
The new ADM-870C has an RS232 port that may be used with a portable printer. The optional printer and cable can download each reading as it is taken, or the entire contents of the memory can be downloaded and printed all at once.
 
RS232 TO COMPUTER
The RS232 link may be used in conjunction with WinWedge® software and a computer to load readings directly into a spreadsheet format for display, analysis, and manipulation. Data may also be downloaded into a word processing format. The WinWedge software comes complete with an instruction manual, license, CD, and full user support for WinWedge from the manufacturer, Tal Technologies, Inc. www.taltech.com.
 
DISPLAY
The ADM-870C has a new display that allows more information to be displayed. It is also easier to read.
 
BACK-LIGHT
The new display has a back-light for use in low-light conditions. The back-light is turned on and off by toggling the ON/OFF key. Note that use of the back-light significantly increases the load on the batteries and reduces the operating time (measured by continuous reading operation) by about half. It is difficult in normal light to tell if the back-light is on or off. The meter will occasionally display a LIGHT ON message to caution against unnecessary use of the back-light. The colon normally found in the third position from the left of the displayed reading will be replaced by two stacked ‘L’ symbols.
 
OFF KEY
The addition of the back-light feature required a change in the way the meter is turned off. To turn the meter off, press SHIFT, then OFF.
 
SPEED-READ

The SPEED-READ feature has been replaced by the TREND mode. The TREND mode offers a continuous series of readings at intervals of about once per second. The accuracy specifications do not apply in TREND mode.

 
BATTERY CHARGE INDICATOR LIGHT
A green LED on the front panel lights when the battery charger is properly connected.
 
STORED READINGS
The reading sequence number is displayed during a sequence of stored readings.
 
STATUS DISPLAY
All selected functions (measurement mode, units, local or standard temperature) may always be read by pressing SHIFT/SHIFT. No reading is taken, and no data is discarded.
 
STORED READING DELETION
Any reading in a stored sequence may be deleted or replaced. The new sum and average for the revised sequence will be calculated and displayed. This replaces the prior method of using the RCL keys to delete the last reading taken.
 
FLOWHOOD MODE SUMS AND AVERAGES
The averages and sums of stored FLOWHOOD mode readings are now displayed three different ways: all readings in sequence, backpressure compensated readings, and nonbackpressure compensated readings. When the STORE key is pressed repeatedly following a reading, the first display is the average of all of the readings in the sequence combined, followed by the average of just the compensated readings, and then the average of the noncompensated readings. Pressing the STORE key repeatedly again will display the sum of all the readings in the sequence, then the sum of the compensated readings, and finally the sum of the noncompensated readings.
 
POWER-ON DEFAULTS
The meter will initialize with the mode and units which were selected when it was last turned off using the meter keypad. This information will not be saved if the meter was forced to shut down automatically due to low voltage or excessive temperature or has been reset.
 
CALC DISPLAY ELIMINATED
The ADM-870C uses a much faster microcontroller than the ADM-870. Calculations occur almost instantaneously. There is no need to display a CALC message.
 
LOW CHARGE DISPLAY
When the battery charge is nearly depleted, the meter will display LOW CHARGE periodically. The colon normally shown following the units for a displayed reading will be replaced by a symbol for an empty battery cell.
AirData Multimeters
The ADM Series
ADM-880C
ADM-870C
ADM-860C
ADM-850L
Meter Comparisons
Meter Maintenance
FlowHoods
CFM-850L

CFM-88L
FlowHood Maintenance
HydroData
MultiMeter
HDM-250 HydroData MultiMeter
Kits
Multi-Temp Kit
8400 Capture Hood Kits

 

ADM-880C | ADM-870C | ADM-860C | ADM-850L | CFM-850L | CFM-88L | HDM-250 | Multi-Temp Kit | Capture Hood Kits | VelGrid


Copyright ©1999-2007 Shortridge Instruments, Inc.  All Rights Reserved.
Layout, content, photos, and imagery may not be used without express permission.
Copyright Policy
www.shortridge.com

Shortridge Instruments, Inc.
7855 E. Redfield Rd.
Scottsdale, AZ  85260-3430 USA
phone 480-991-6744  fax 480-443-1267